How can I tell if my thermostat is bad instead of just wired wrong?
With power on, briefly jump a wire between R and W at the wall plate or control board. If the furnace fires immediately, the thermostat is the likely failure point. If nothing happens, the fault is upstream in the wiring or transformer.
Do electric fireplaces need special wiring?
The wire itself is ordinary. What they need is capacity. A 1,500 watt unit draws about 12.5 amps, past the 12 amp continuous limit of a 15 amp circuit, so it usually needs its own 20 amp circuit. Hardwired and 240V models always need new wiring run by an electrician.
How much does it cost to rewire a 1,500 square foot house?
Roughly $8,000 to $15,000 for a full rewire, more if the panel also needs replacing or walls are hard to access.
Can I still use other outlets on the same circuit if one smells like burning?
No. The overheating connection is usually inside a box you can't see, and the other outlets on that run may be fed straight through it. Loading them pushes more current into a spot that is already too hot. Leave the breaker off until an electrician inspects the circuit.
How often should I get an electrical inspection?
Every three to five years for most homes. Homes 40 years old or older should be checked every one to two years. Schedule one after any major renovation before the walls close.